Technical Rider v3.0 // High Luminosity Config

ARCHITECTURAL
PROJECTION MAPPING

Comprehensive Technical Documentation for Large-Scale Outdoor Environments.

01 // Project Overview

Surface & Triple-Stack Luminosity

0
Total Sq. Meters
0
Total ANSI Lumens (9 Units)
0
Estimated Lux / Wall

Environmental Challenges

Outdoor operations face volatile variables. Ambient light pollution from street lamps, humidity affecting lens clarity, and high-velocity wind loads on truss structures are primary risks. Dust management for projector intake is critical.

High-Impact Configuration

By utilizing 3 projectors per wall (9 units total), we achieve a high-density 141 Lux average. This configuration allows for either extreme brightness via triple-stacking or ultra-wide seamless blending for complex architectural textures.

02 // System Architecture

Signal Flow & Topology

TouchDesigner REAL-TIME ENGINE SPOUT Resolume Arena WARPING / MAPPING / OUTPUT RTX 4090 x2 12x 4K OUTPUTS WALL 1: CLUSTER (3x 30K) WALL 2: CLUSTER (3x 30K) WALL 3: CLUSTER (3x 30K) 63A 3P 10G NET

The Triple-Stack Pipeline

With 9 total projectors, Resolume handles a 12-output canvas (9 active, 3 backup/pre-viz). GPU texture sharing remains the bottleneck; we recommend a dual-RTX 4090 setup or a dedicated rack-mounted media server for this scale.

Hardware Requirement

Minimum: Intel Xeon or i9-14900K, 128GB DDR5, Dual NVIDIA RTX 4090 with Quadro Sync II for frame-perfect output synchronization across the 9-projector array.

03 // Power & Infrastructure

Electrical Load Requirements

  • Projector Load (9x)28,800W
  • Media Workstations (2x)3,000W
  • Network/Misc1,000W
  • Total Peak Draw32,800W

Critical Provisioning

The increased load requires two separate 63A 3-Phase feeds or a massive 125A 3-Phase service. A 100kVA silenced generator is required for full system redundancy.

Note: UPS backup is mandatory for the entire control rack to prevent cold-starts during power fluctuations.

04 // IP Assignment

Network Config (9 Units)

Servers192.168.1.10-11
Wall 1 Cluster192.168.1.101-103
Wall 2 Cluster192.168.1.104-106
Wall 3 Cluster192.168.1.107-109
Subnet Mask255.255.255.0

05 // Calibration

Stacking Workflow

1
Triple-Stack Alignment

Pixel-perfect convergence of 3 units per surface. Mandatory use of motorized lens shift.

2
Warping & Blend

Complex geometric correction in Resolume. Advanced edge blending for 80m width.

3
Luminosity Balancing

Uniformity check across 9 units. Monitoring heat signatures of stacked chassis.

06 // Outdoor Protocol

Protection & Safety

IP-Enclosures

9 units require specialized stacking enclosures. Thermal management is critical as three Christie 30K units in close proximity generate massive heat (>30,000 BTU/hr per cluster).

Structural Stability

With 3 projectors per tower, the weight exceeds 450kg per cluster. Towers must be rated for high wind loads with significant ballast (min 2000kg per tower base).